ข้อมูล
น้ำหนัก
บาร์โค้ด
ลงสินค้า
อัพเดทล่าสุด
รายละเอียดสินค้า
Description

Technical parameter

  • Measuring range : 10...500 / 4000 NTU
  • Temp measure range : 0.0...60.0℃Stainless
  • Shell material : steel5m(standard)
  • Cable length : ±5.0%FS
  • Accuracy : Ip68
  • Protection grade : <3barImmersion type
  • Pressure range : 10NTU
  • Power supply : DC9-30V(Recommend 12V)
  • Output : 4...20mA,maximum load750Ω, RS485/MODBUS-RTU

Interface Description

          Before use, please read this instruction carefully before use, In the measurement process, if there is dirt, adhesive or encrust on the sensor , the measured value will be inaccurate or fluctuate. It should be cleaned and calibrated in time.

Line Color

Description

Green

DSHIELD

Brown

DC9...30V (recommend DC12V)

Blue

DC0V(I-)

Gray

4...20mA(I+)

White

RS485A

Black

RS485B



Sensor communication

 Communication description (factory default)

baud rate

9600( default )

data bit

8

stop bit

1

check bit

no

address

1 ( default )

 

 Host computer transmission format

 

Data type

Description

Remarks

Integer

16 bit integer

The high and low bytes of the word component are not reversed

Example: 0x 0032 to decimal number is 50

Floating point number

(CDAB)
3412

The high-low word of the double-byte component is reversed, but the high-low byte of the word is not reversed.

Example: 72 37 41 DB transfer to floating point number, CDAB change order is ABCD, ie 41 DB 72 37 transfer to floating point is 27.4

 

 Function code description

  • This product supports 03,06,16 and other common function codes
  • The output register uses 16 function codes when writing double word data or writing multiple data in batches

03

Read single or multiple registers

06

Write single register

16

Write multiple registers

 

 Read floating point number

  • Host computer transmission format:

 

ID address

Function code

Register start address

Qty of registers

CRC16

Example 1 Read measured value

0x 01

0x 03

0x00 0x01

0x00 0x02

0x95 0xCB

  • Slave computer response format:

 

ID address

Function code

Qty of registers

Read register data in hexadecimal floating point number

CRC16

Example 1 Measured value return

0x 01

0x 03

0x04

C
0x2C

D
0x81

A
0x40

B
0x91

0x52 0xE7

Note: 72 37 41 DB transfer to floating point number, CDAB change order is ABCD, ie 41 DB 72 37 transfer to floating point is 27.4


Read integer

  • Host computer transmission format:

 

ID address

Function code

Register start address

Qty of registers

CRC16

Example 1 Read warning status

0x01

0x03

0x00 0x07

0x00 0x01

0x35 0xCB

  • Slave computer response format:

 

ID address

Function code

Qty of registers

Read register data in hexadecimal integer

CRC16

Example 1 Warning status return

0x 01

0x 03

0x 02

A
0x00

B
0x00

0xB8 0x44


Write floating point number

  • Host computer transmission format:

 

ID address

Function code

Register start address

Qty of registers

Qty of bytes

Write register data in hexadecimal floating point number

CRC16

Example 1 Write Measured value offset

0x01

0x10

0x00 0x12

0x00 0x02

0x04

C
0x00

D
0x00

A
0x3F

B
0x80

0x63 0x2A

  • Slave computer response format:

 

ID address

Function code

Register start address

Qty of registers

CRC16

Example 1 Measured value offset return

0x 01

0x 10

0x00 0x12

0x00 0x02

0xE1 0xCD

Note: the measured value is offset by 1.00, floating point number 1.00 converts to hexadecimal 0X3F800000, transpose the high and low positions 0X00003F80 and write 0X0012.

Write integer

  • Host computer transmission format:

 

ID address

Function code

Register start address

Write register data in hexadecimal integer

CRC16

Example 1 Write device address

0x01

0x06

0x00 0x19

A
0x00

B
0x02

0xD9 0xCC

  • Slave computer response format:

 

ID address

Function code

Register start address

Write register data in hexadecimal intege

CRC16

Example 1 Device address return

0x 01

0x 06

0x00 0x19

A
0x00

B
0x02

0xD9 0xCC

Note: change the local computer address 1 to address 2 and write the hexadecimal number 0x 00 02 into register 0x 00 19.

เงื่อนไขอื่นๆ
Tags

วิธีการชำระเงิน

บมจ. ธนาคารกสิกรไทย สาขาสุทธิสาร ออมทรัพย์
ธนาคารไทยพาณิชย์ จำกัด (มหาชน) สาขาบิ๊กซี สะพานควาย ออมทรัพย์
รายการสั่งซื้อของฉัน
เข้าสู่ระบบด้วย
เข้าสู่ระบบ
สมัครสมาชิก

ยังไม่มีบัญชีเทพ สร้างบัญชีใหม่ ไม่มีค่าใช้จ่าย
สมัครสมาชิก (ฟรี)
รายการสั่งซื้อของฉัน
ข้อมูลร้านค้านี้
ร้านSumtech
Sumtech
Wecome to Summation Technology Co., Ltd. เราให้บริการด้านการวัดและควบคุมในอุตสาหกรรมการผลิต, อุตสาหกรรมการเกษตร แบบครบวงจร หัวใจหลักในการดำเนินธุรกิจของเรา คือ มุ่งมั่นในการพัฒนา สรรหา และประยุกต์เทคโนโลยีต่างๆ ให้เหมาะสมกับการใช้งาน และทันสมัยเพื่อเพิ่มประสิทธิภาพและลดต้นทุนต่างๆ ในการผลิตของลูกค้า ให้การบริการแบบครบวงจร
เบอร์โทร : 02-270-0500
อีเมล : sumtech2009@gmail.com
ส่งข้อความติดต่อร้าน
เกี่ยวกับร้านค้านี้
สินค้าที่ดูล่าสุด
ดูสินค้าทั้งหมดในร้าน
สินค้าที่ดูล่าสุด
บันทึกเป็นร้านโปรด
Join เป็นสมาชิกร้าน
แชร์หน้านี้
แชร์หน้านี้

TOP เลื่อนขึ้นบนสุด
พูดคุย-สอบถาม